CABINET PREPARATION
STEP 2: CABmNET PREPARATmON
1. The range is a free standing
unit. Hfthe unit is to be placed adjacent to cabinets, the clearances
shown in Fig. 3 are required.
The same cHearances appHy to isHand instaHHations.
2. The range can be pHaced in various positions
with respect to the cabinet front, with the front
either flush or projecting,
depending
on the countertop
depth (See Fig. 5, page 6).
00
L !
35-3/8"max.for levelcounter,
3&3/4" max.with range
leveling legsfully extended
"As definedin the
"National F uel G as Code"
(ANSI Z223J,latestedition).
Therangeheight[sadjustable. T he[eve[of the
range top must beat the same [eve[orabovethec0untertoplevel.
A)
7q/2"
m 18"mJn.
C) 3"
D)
13"max.
E) 4-1/2" (gas)
F) 11"(electrkal)
FIG. 3
Flex Line
"'-..
to Range
2" Maximum
Protrusion
from Wall
for Gas Supply
FIG. 4