Wiring the Redundant Power Inputs

MOXA EtherDevice Server has two DC inputs located on the top panel. Top and front
views of one of the terminal block connectors used to connect to a DC power source are
shown here. Note that when viewed from this angle, the negative DC wire goes in the
terminal block connector's left terminal, and the positive DC wire goes in the right
terminal.
Wiring MOXA EtherDevice Server
STEP 1: Insert the negative/positive DC wires into the left/right
terminals (1) on the top of the terminal block connector.
STEP 2: To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp screws (3) on the
front of the terminal block connector.
STEP 3: Insert the plastic terminal block connector prongs (4) into
the terminal block receptor, which is permanently fixed to MOXA
EtherDevice Server's top panel.
STEP 4: Use a small flat-blade screwdriver to tighten the two screws
(2) on the top of the terminal block connector to fix it to the terminal
block receptor.
MOXA EtherDevice Server User's Manual 3-5