Error List - WisyCom MPR30-IEM User Manual

High performance true diversity receiver
Hide thumbs Also See for MPR30-IEM:
Table of Contents

Advertisement

E
RROR LIST
When an error occurs, the receiver
A.
shows a message on the display
and for some error types
B.
increases the errors counter in the info menu
C.
inserts the error type and code on the error list in the info menu
When the error is solved, the message on the display disappear, but the error information
(code and description) are available on the error list in the Info menu (only for some error, see
the below table).
NOTE
: When the receiver is reset the error information (code and error type on the list) are
1
lost, with the exception of errors codes 87/88/89/8A.
NOTE
: To reset the error counter and the errors list, it is necessary to contact Wisycom.
2
Errors
HW init failed
Battery Low
Battery charge failed
I2C communication error
Device ID copy1 invalid
Memory recovered
Device ID copy2 invalid
Memory recovered
RF copy1 invalid
Memory recovered
RF copy2 invalid
Memory recovered
PLL unlocked
CH mem header
Param mem header
Message on display
(A)
HW init failed
Battery Low
Battery charge failed
I2C communication error I2C access failed
Device ID copy1 invalid
Memory recovered
Device ID copy2 invalid
Memory recovered
RF copy1 invalid
Memory recovered
RF copy2 invalid
Memory recovered
-
-
-
Error type
(C)
Device ID copy 1
Device ID copy 2
RF mem copy 1
RF mem copy 2
PLL unlocked
CH mem header
Param mem header
Code
(C)
04
87
88
89
8A
84
85
86
14