Caution: The fuser unit is an integral part of the color imaging
process and is also very expensive to replace. The fuser life will be
shortened or the fuser permanently damaged if the cleaning pad is
not installed properly or if proper care is not taken to change the
cleaning pad and oil bottle when needed. This type of damage is not
covered under warranty or service contract.
The first oil bottle and cleaning pad will last approximately 1,500
pages. After that, they will last approximately 3,000 pages.
1
Turn off the main power switch on the back of the printer.
2
Remove the top cover.
3
Pull up on the paper exit unit latch and then tilt the paper exit
unit back and down to open it.