Establishing Communication With The Power Supply; Figure 2-28 Ascii Setup Dialog Box - Xantrex 850W Operating Manual

Gpib and ethernet interface for xtr series programmable dc power supplies
Table of Contents

Advertisement

Ethernet (ENET)
3. Click the ASCII Setup button.
4. Verify that the ASCII Sending and ASCII Receiving boxes are

Figure 2-28 ASCII Setup Dialog Box

5. Click OK.

Establishing Communication with the Power Supply

To establish communication with the power supply:
1. In the main HyperTerminal window, click Call. See Figure 2-29.
2. To verify that the XTR unit is connected and functioning, type the
3. Verify that the XTR unit responds with the ID string.
4. To save your session for future use, click File > Save As....
2-22
The ASCII Setup dialog box will appear as shown in Figure 2-28.
checked as shown in Figure 2-28.
following command "*ADR <#>;*IDN?" where the
be replaced by the address assigned to the power supply in the
"Selecting ENET as the Communication Port" on page 2–17.
See Figure 2-30.
<#>
should