Tonal Signal Test - Muratec MFX-1300 Field Engineering Manual

Facsimile system
Hide thumbs Also See for MFX-1300:
Table of Contents

Advertisement

Press STOP to exit the relay test mode.
5. Press STOP again to return to standby mode.

3.13.2 Tonal Signal Test

The tonal signal test permits the unit's output tones to be monitored.
Note: To monitor the tones, an external monitoring device must be connected to the telephone line jack.
1. Press Program key, *, C (03).
Board Number?
2. Press the numeric keypad 0 (zero) to select the optional board number for the fax unit.
To select the optional board number for the second phone line, press 1 (one).
Relay Test
3. Press
once(Tonal Test 1) or twice(Tonal Test 2) to select your desired tonal signal test, then press
ENTER.
Note: Regarding the Tonal Test 1 and 2, refer to the table in next step.
Tonal Test 1
4. To output a desired tonal signal, press the corresponding numeric key and one-touch key as shown in the
following table. For example, to monitor the 2100 Hz CED tone, press numeric key 9. The output signal will
begin. A different output signal can be selected by pressing corresponding numeric key and one-touch key.
Note: It may take several moments for output signal to change.
Numeric key
1
2
3
4
5
6
Tonal Test 1
One-
Signal
touch key
rate
01
V.27ter
02
03
V.29
04
05
V.17
06
Signal
None (stop signal)
462 Hz tone
1080 Hz tone
1300 Hz tone
1650 Hz tone
1700 Hz tone
Symbol
Data rate
rate
1200 baud 2400 bps
1600 baud 4800 bps
2400 baud
7200 bps
9600 bps
2400 baud
7200 bps
9600 bps
3-73
Numeric key
7
8
9
*
FSK white (all 0)
#
FSK black (all 1)
0
Tonal Test 2
One-
Signal
touch key
rate
01
V.34
02
03
04
05
06
Signal
1800 Hz tone
1850 Hz tone
2100 Hz tone
FSK W1 : B1
Symbol
Data rate
rate
3000 baud
4800 bps
7200 bps
9600 bps
12000 bps
14400 bps
16800 bps