Muratec MFX-1300 Field Engineering Manual page 71

Facsimile system
Hide thumbs Also See for MFX-1300:
Table of Contents

Advertisement

Unique Switch a:0 — Dialer
Initial
Switch
Setting
7
0
Factory use only
6
0
Congestion tone detection
0: No
1: Yes
5
1
Ring back tone wait time
(seconds)
4
0
Switch 5:
Switch 4:
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
1
Factory use only
Unique Switch a:1
Unique Switch b:0 - Transmission
Initial
Switch
Setting
7
0
Factory use only
6
0
Transmission when disable to
detect first NSF
0: Transmit with the standard
protocol
1: Retry to detect NSF
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
1
The number of times PPR is detected during ECM transmission
1 time 2 times 3 times 4 times
0
1
0
0
Unique Switch b:1
Adjust
Setting this switch to "0", ignores telephone line
congestion tones.
Sets the time until the ring back tone begins after
answering an incoming call in the Fax/Tel Ready or
3.0 3.3 3.6 3.9
Tel/Fax Ready mode.
0
0
1
1
0
1
0
1
a:9 --- Factory use only
Adjust
Determine the action when disable to detect first
NSF.
0
1
1
1
0
1
b:5 --- Factory use only
3-41
Usage/Comments
Usage/Comments

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1600Mfx-1700Mfx-1200

Table of Contents