7.3.9
Lengthening water
delivery time by setting
pauses
The default time required for making a full
container of coffee can be lengthened by setting
pauses. This is, for example, necessary when
very finely ground coffee or very soft water is
used. Then some more time is needed for the
water to go through the coffee filter, otherwise it
will overflow. The capacity is reduced. This is
indicated in %.
– Default setting to 100%, so no pauses.
– The setting range is between 100% and 50%,
to be set in 5% steps. After the setting, the
machine calculates the pause schedule itself.
It can, however, be set to when the first
pause should come.
– The setting must be determined by
experience by making coffee.
– The minimum amount that can be set for the
first pause is the volume of the filter cone
+25%.
B5HW
2 litres
B10HW
4 litres
B20HW
8 litres

Table 11 Minimum amount first charge

%
G
H
I
J
K
L
M

Fig. 46 Pause time 100%

D Press selection key (N.)⇑ until fig.46 appears
on the display.
D Press programming key (G.).
– The position beside the programming key
starts flashing.
D Press selection key (M.)⇓ or (N.)⇑ to select the
desired programme.
– The enter symbol ↵ appears on the display.
36
version
1.0
D Press confirmation key (L.) to confirm the
adjustment.
D Press programming key (I.).
TIP
– This can only be done when the percentage
D Press selection key (M.)⇓ or (N.)⇑ to select the
desired amount of the first charge.
– The enter symbol ↵ appears on the display.
D Press confirmation key (L.) to confirm the
adjustment.
D Press selection key (N.)⇑ to go to the next
setting or press stop key (K.) to exit the
programming menu.
7.3.10 Setting dripping–on time
When the hot water supply through the spray head
has stopped, it will take a while until the filter pan
also stops dripping. The time required for this
varies with different coffee brands and/or grinds.
Therefore this dripping–on time can be changed.
– The default setting is on 120 seconds.
– The setting range is from 0 – 600 seconds in
2,5 litres
G
5,0 litres
H
10,0 litres
I
J
Fig. 47 Dripping–on time
The dripping–on time can be set as follows:
D Press selection key (N.)⇑ until fig.47 appears
on the display.
D Press programming key (G.).
N
– The value beside the selection key starts
D Press selection key (M.)⇓ or (N.)⇑ to select the
desired number of seconds.
– The enter symbol ↵ appears on the display.
D Press confirmation key (L.).
– The desired number of seconds has been
D Press selection key (N.)⇑ to go to the next
setting or press stop key (K.) to exit the
programming menu.
is not set to 100%.
10 seconds steps.
K