Remove The Hot Water Valve; Remove The Boiler - BRAVILOR BONAMAT Sego Technical Manual

Hide thumbs Also See for Sego:
Table of Contents

Advertisement

2.14.4 Remove the hot water valve

A
B

2.14.5 Remove the boiler

A
B
B
D
C
12
A
C
B
A
E
D
► When the boilers is drained, hot water comes out of
the drain hose, therefore take protective measures.
Step 1
• open the door
• remove the drip tray and waste bin
• pull out the drain hose
• place a container under the drain hose
• remove the tightening plug
• wait until all the water has drained out of the boiler
• replace the tightening plug
Step 2
• disconnect the wiring
• disconnect the 2 thin hoses
• loosen the bolt
B
• remove the hot water valve
Step 1
• drain the boiler as in
Step 1
► When the boiler is drained, hot water comes out of the
drain hose, therefore take protective measures.
Step 2
• remove the thermostat, see
• remove the temperature sensors from the boiler, see
section 2.14.3
• remove the hot water valve, see
• remove the hose on top of the boiler
• loosen the 2 metal boiler clamps
boiler up
Step 3
• disconnect the pressure hose
elements
underneath the boiler
D
• pull the boiler supply
• open the 2 metal boiler clamps to remove the boiler
• remove the isolation parts
A
B
C
A
of
section 2.14.4
section 2.14.2
section 2.14.4
A
and move the
B
and wiring of the
C
out of the boiler
E

Hide quick links: