Malfunctioning analysis general

Symptom:
1. At switching on the machine
with the main switch, the
temperature setting flashes
with the figures 00.
2. Nothing appears on the
display.
di
l
3. The water temperature is
not right.
4. Time is not set correctly.
5. The machine does not work
according to the timer.
B5 HW (230V)
Symptom:
1. Main fuse keeps popping
out.
2. Maximum amount of coffee
to be made does not match
the machine type.
B (HW)
(AFTER 2000)
LIST OF MALFUNCTIONS
Possible cause:
The machine will first start
calibrating to ensure an optimum
setting.
The switch is off.
The supply voltage has been
interrupted.
The temperature has been set too
high or loo low.
All B(HW) machines are standard
provided with a timer. This must,
however, be activated.
LIST OF MALFUNCTIONS
Possible cause:
The power can be too high >16A
for a B5 HW (230 V).
Incorrect (software) setting.
ECopyright Bravilor Bonamat B.V.
Actions:
Wait until the machine is ready
("25 minutes).
Switch ON/OFF switch ON.
Connect the supply voltage.
Adjust the water temperature.
Set the correct time and day.
Activate the timer.
Actions:
Activate the preferential
programme.
Select the right machine type.

Advertisement

loading
Need help?

Need help?

Do you have a question about the B HW Series and is the answer not in the manual?

Questions and answers

شريف امين سرور جوهر
January 16, 2025

ممكن كود اعطال

Summary of Contents for BRAVILOR BONAMAT B HW Series

  • Page 1: Malfunctioning Analysis General

    The power can be too high >16A Activate the preferential out. for a B5 HW (230 V). programme. 2. Maximum amount of coffee Incorrect (software) setting. Select the right machine type. to be made does not match the machine type. ECopyright Bravilor Bonamat B.V.
  • Page 2 9. The machine steams while The machine is calcified. Descale the machine earlier or making coffee and the lower the descaling indicator value. coffee making takes too much time. ECopyright Bravilor Bonamat B.V.
  • Page 3: Hot Water System

    Boiling dry safety device applied. Check the safety device and reset this if necessary by pressing the button. 4. The hot water system An element is defective. Replace the element. warms up very slowly. ECopyright Bravilor Bonamat B.V.
  • Page 4: Display Messages And Their Meanings