Starting Descaling Program Coffee–Making System; Starting Descaling Programme Hot Water System; Resetting The Day Counter Of The Hot Water System; Fig. 54 Resetting Day Counter Coffee-Making System - BRAVILOR BONAMAT B5HW Operating Instructions Manual

Round–filter coffee brewer with hot water tap
Hide thumbs Also See for B5HW:
Table of Contents

Advertisement

Number of
Water hardness
litres
lit
5
± 250 litres
18 –30
32 – 55
± 500litres
12 –18
22 – 32
± 1000litres
8 –12
15 – 22
± 1500litres
4 − 8
± 2000litres
0 – 4
4,0 °dH =
0,714 mmol/litres
5,6 °dH =
1,000 mmol/litres
8,0 °dH =
1,429 mmol/litres
12,0 °dH =
2,143 mmol/litres
18,0 °dH =
3,214 mmol/litres
30,0 °dH =
5,357 mmol/litres
10,0 °TH =
1,000 mmol/litres

Table 13 Water hardness

7.3.16 Starting descaling
programme hot water
system
See § 7.2.4.
7.3.17 Starting descaling program
coffee–making system
See § 7.2.3
7.3.18 Resetting the day counter
of the hot water system
The total amount of hot water made per day can
be read. The day counter can be reset daily. This
is done as follows:
G
H
I
J
K
L
M
Fig. 53 Resetting the day counter of the HW
system
D Press selection key (M.)⇓ until fig.53 appears
on the display.
D Press selection keys (M.)⇓ and (N.)⇑
simultaneously.
– The day counter is reset.
D Press selection key (N.)⇑ to go to the next
setting or press stop key (K.) to exit the
programming menu.
40
version
1.0
5
Description
hard
fairly hard
average
7 − 15
soft
0 − 7
very soft
D
N
7.3.19 Resetting day counter
coffee–making system
TIP
– The amount is only given in litres. Even if the
amount at § 7.3.1 has been set to cups, jugs
or us gallons.
– Press the selection key (M.)⇓ a bit longer (about
2 sec.) than in the previous programme sections
to view and/or adjust the counter readings below.
G
H
I
J
K
L
M
Fig. 54 Resetting day counter coffee–making system
The total amount of coffee made daily can be read.
The day counter can be reset daily. This is done as
follows:
D Press selection key (M.)⇓ until fig.54 appears
on the display.
D Press selection keys (M.)⇓ and (N.)⇑
simultaneously.
– The day counter is reset.
D Press selection key (N.)⇑ to go to the next
setting or press stop key (K.) to exit the
programming menu.
ECopyright Bravilor Bonamat B.V.
D
N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B10hwB20hw

Table of Contents