7.3.6
Settings hot water
system
The hot water temperature can be set between
88_C – 3_C under the boiling point. The default
temperature is _Celsius, but this can also be set
to _Fahrenheit.
The automatic boiling point determination
programme can be reset (§ 7.3.6.2). This can
only be done when the water has not yet
reached 85_C (at sea level). Otherwise drain a
little water and refill with cold water (till maximum
6,5 cm under the rim of the kettle).
7.3.6.1
Setting temperature and
degrees Celsius or Fahrenheit
G
H
I
J
M
K
L

Fig. 40 Setting the temperature

D Press, after having entered the principal user
PIN code, 3 time selection key (N.)⇑ until
fig.40 appears on the display.
D Press programming key (G.).
– The position beside the programming key
starts flashing.
D Press selection key (M.)⇓ or (N.)⇑ to select the
desired temperature.
– On the display beside the programming key
(I.) there is the "C" of Celsius.
D If desired, press programming key (I.) to
change the temperature into Fahrenheit. The
"C" changes into "F".
– The enter symbol ↵ appears on the display.
D Press confirmation key (L.) to confirm the
adjustment.
D Press selection key (N.)⇑ to go the next setting
(§ 7.3.7.1) or press stop key (K.) to exit the
programming menu.
32
version
1.0
7.3.6.2
D Press, after having entered the principal user
PIN code, 3 time selection key (N.)⇑ until
fig. 40 appears on the display.
D Press for about 20 seconds programming key
(H.).
– The automatic boiling point determination
– A zero starts flashing on the display.
– The programme takes about 15–25 minutes.
TIP
– If the water in the kettle is cold, drain it
– When the automatic boiling point
N
D Press selection key (N.)⇑ to go the next setting
(§ 7.3.7.1) or press stop key (K.) to exit the
programming menu.
Resetting the automatic
boiling point determination
programme
programme is activated.
This depends on the temperature of the
water in the kettle.
completely and pour hot water (ca. 70 °C)
into the kettle till maximal 6,5 cm under the
rim of the kettle. This will shorten the time of
the automatic boiling point determination
programme till about 15 minutes.
determination programme has finished,
the program returns to the users menu, the
starting screen appears in the display, see
fig. 8 , § 4.1.1. Also the temperature has
been reset to the default setting (96 °C, at
sea level).