1.11 Step by step programming (continued)

1.11.1 S
WITCHING THE MIXER ON OR OFF
WHEN TAPPING LARGE CUPS
1. Select program "Switching the mixer on
or off for large cups". Figure 16
appears in the display.
2. Press the left-hand side of the setting
key à
(13) to switch the mixer off,
see fig. 17.
3. Press the right-hand side of the
ß (13) to switch the
setting key
mixer on, see fig. 16.
The default setting is: ON.
1.11.2 S
ETTING THE WATER TEMPERATURE
1. Select program 'setting the water
temperature'. Figure 18 appears in
the display.
2. The setting ranges from 80 C through
90 C.
3. Select the required setting with the
start button
.
− press on the right-hand side of the
setting key
temperature.
− press on the left-hand side of the
setting key à
temperature.
The default setting is 85°C.
Fig. 16
Fig. 17
Fig. 18
ß for a higher water
for a lower water
1.11.3 S
ETTING DESCALING SIGNAL
1. Select program 'setting descaling
signal', see figure 19.
− The setting ranges from 0 through 5.
− This setting allows you to set the
number of litres of beverage that
can be brewed, after which the
machine must be descaled.
− This setting depends on the
hardness of the water. The harder
the water, the sooner descaling is
necessary.
2. Select the required setting with the
setting key
− press on the right-hand side of the
setting key
− press on the left-hand side of the
setting key
The default setting is: ± 1000 litres,
setting 3.
Setting
Number of
litres
no signalling
1
±
250 litres 18 till 30 hard
2
±
500 litres 12 till 18 fairly hard
3
± 1000 litres 8 till 12
4
± 1500 litres 4 till 8
5
± 2000 litres 0 till 4
°
4,0
dH = 0,714 mmol/litres
°
5,6
dH = 1,000 mmol/litres
°
8,0
dH = 1,429 mmol/litres
°
12,0
dH = 2,143 mmol/litres
°
18,0
dH = 3,214 mmol/litres
°
30,0
dH = 5,357 mmol/litres
Fig. 19
ß(13).
ß (=ascending).
ß (=descending)
Water hardness
°dH
description
average
soft
very soft
9