3.4 System Test
Subtest 07
DMI read
Reads the factory setting for the serial and DMI numbers.
Model Name
Version Number
Serial Number
Model Number
PCN/BND Number
UUID Number
Press [Enter] to EXIT
To exit this subtest and return to the SYSTEM TEST menu, press Enter.
Subtest 08
DMI write
The following messages appear in order. Input each information. (If you do
not replace the PCB, the DMI information should not be changed.)
1. "
Enter Model Name ?
Input the computer's model name and press Enter. (e.g. TECRA M2V)
2. "
Enter Version Number ?
Input the computer's version number and press Enter. (e.g. PTM2VU-
AAAA1)
3. "
Enter Serial Number ?
Input the computer's serial number and press Enter. (e.g. Y3017904JU)
4. "
Enter Model Number ?
Input the computer's sales model number and press Enter. (e.g. PTM2VU
-AAAA1)
5. "
Enter Bundle Number ?
Input the computer's PCN/Bundle number and press Enter. (e.g.
PCN1391CCZ01/S3A1320D990)
6. "
Write data OK (Y/N) ?
When Y is press, the DMI information is written to the Flash-ROM.
7. "Create DMIINFO TXT (Y/N) ?" is displayed.
Press Y, then the DMI information (text data) is written to the Floppy disk,
etc.
TECRA M2V Maintenance Manual (960-476)
: XXXXXX
: XXXXXX-XXXXX
: XXXXXXXXXX
: XXXXXX-XXXXX
: XXXXXXXXXXXXXXXXXXXX
: XXXXXXXXXXXXXXXXXXXXXXXXX
" is displayed.
"
"
"
"
"