Audio Files Switch
The Audio Files switch displays the following commands for
importing and exporting data into Pro Tools:
• Import Audio: File > Import > Audio
• Import MIDI: File > Import > MIDI
• Audio To Trk: File > Import > Audio To Track
• MIDI To Trk: File > Import > MIDI To Track
• Import SesDat: File > Import > Session Data
• Export Selctd: Regions List > Export Selected As Files
Show/Hide Switch
The Show/Hide switch displays commands from the
Show/Hide Tracks List menu.
The Show/Hide switch has two pages of Soft Key functions.
Show/Hide Switch (Page 1)
• Show All: Show All Tracks
• Hide All: Hide All Tracks
• Show Selctd: Show Only Selected Tracks
• Hide Selctd: Hide Only Selected Tracks
• Show Inactv: Show Only Inactive Tracks
• Hide Inactv: Hide Only Inactive Tracks
Show/Hide Switch (Page 2)
• Show Audio: Show Only Audio Tracks
• Hide Audio: Hide Only Audio Tracks
• Show Aux: Show Only Auxiliary Inputs
• Hide Aux: Hide Only Auxiliary Inputs
• Show MIDI: Show Only MIDI Tracks
• Hide MIDI: Hide Only MIDI Tracks
Show/Hide Switch (Page 3)
• Show Instmt: Show Only Instrument Tracks
• Hide Instmt: Hide Only Instrument Tracks
You can select multiple Show/Hide categories by holding Shift
while pressing the corresponding Soft Key.
74
D-Command Guide
Console Preferences
User
Operation
Meter
switch
switch
switch
Console Preferences
The Console Preference switches control D-Command prefer-
ences only, and do not affect the Pro Tools on-screen display.
User Switch
The User switch displays a user-configurable, custom set of
Soft Keys, chosen from any of the other Soft Key displays. To
cycle through both pages of User Soft Key selections, repeat-
edly press the User switch.
To add a Soft Key command to a User Soft Key selection:
In the Soft Keys section, press the User switch repeatedly to
1
display the page (Page 1 or Page 2) where you want to add the
operation.
Press the Soft Keys to display the page containing the oper-
2
ation you want to add.
Hold Control (Windows) or Command (Mac) and press the
3
Soft Key for the operation.
To remove a Soft Key command from the User Soft Key selection:
Press the User switch repeatedly to display the operation
1
you want to remove.
Hold Control (Windows) or Command (Mac) and press the
2
Soft Key for the User operation.
Meter Switch
The Meter switch displays the following D-Command meter
preferences:
SndMtr (Send Meters) Toggles send metering on channel ro-
tary encoders on and off.
InsMtr (Insert Meters) Toggles plug-in metering on channel
rotary encoders on and off.
Meters Toggles channel metering between pre- and post-fader
modes.
CtrMtr (Center Meters) Toggles the 8-channel meter display
on the Main Unit meter bridge between main output levels
and the focused track.
RefLvl (Reference Level) Lets you change the D-Command
meter display to help monitor program material with respect
to different reference levels.