Front Panel
Generator/Parameter
Switches
The Generator/Parameter controls are labeled
Set, Down, Up, and Run/Stop/Clear/Esc. In addi-
tion to their primary generator functions, these
switches provide front panel access to most
SYNC peripheral parameters.
Features Not Accessible from the Front Panel
Controls
The front panel provides access to all SYNC pe-
ripheral features except the following, which
can be controlled using Pro Tools or the SYNC
Setup software utility (available on Windows
only):
• Remote-Only Mode/Front Panel Lockout
• Changing Window Burn Size, Vertical Posi-
tion, Horizontal Position, and Color
• GPI (General Purpose Interface) functions
• Variable Speed Offset (VSO)
For a listing of available parameters, see Table 5
on page 34.
RUN/STOP
SET
DOWN
UP
CLEAR
Generator/Parameter Switches
Set
The Set switch has three primary functions:
When time code is displayed Press Set once to
change the Display from time code to parameter
names.
When a parameter name is visible Press Set once
to change the Display to show parameter values.
LTC
POSITIONAL
VITC
REFERENCE
BI-PHASE
DF
GENERATE
When a parameter value is visible Press Set once
to set the value for that parameter and return
the Display to time code.
Down and Up
The Down and Up switches scroll through pa-
rameter names or values:
When a parameter name is visible Press the
Down and Up switches to scroll through the pa-
rameter names (for example, from "SET GEn" to
"VIdEo SY").
When a parameter value is visible Press the
Down and Up switches to scroll through the
range of values for the current parameter.
When entering time code values Press the Down
and Up switches simultaneously to cycle
through the hours:minutes:seconds:frames
fields in the time code display.
Run/Stop/Clear/Esc
The Run/Stop/Clear/Esc switch has several func-
tions, depending on the current mode:
While generating time code Press
Run/Stop/Clear/Esc to start or stop the time
code generator when the SYNC peripheral is in
Generator Preset mode.
While time code is being displayed Press
Run/Stop/Clear/Esc to reset the counter when-
ever time code is visible in the LED Time Code
display.
Otherwise, the Run/Stop/Clear/Esc switch serves
as a Cancel switch.