Restoring Factory Settings

A SYNC peripheral can be reset to its default fac-
tory settings.
To reset all parameters to default settings:
Switch off power to the SYNC peripheral and
1
wait at least 10 seconds.
Hold both the Up and Down front panel
2
switches and turn on power to the SYNC periph-
eral. Do not release the Up and Down switches
until the display reads "FAC-CFG."
Resetting factory settings does not reset the
SYNC peripheral oscillator. See "Calibrat-
ing the SYNC Peripheral Oscillator" on
page 66 for information.
68
SYNC HD Guide
Factory Default Settings
The following table lists the default settings of
each parameter.
SYNC Peripheral Defaults
Parameter Name
Set Generator Start Time
Digital Reference
Sample Freq (Rate)
VITC Insertion
Pull Rates
Base Clock
(VITC) Reader Line
(VITC) Generate Line
Window Burn On/Off
Freewheel Duration
LTC Output level
Servo gain
Pitch Hold
Bi-Phase Pulse-per-frame
Bi-Phase Signal
Video System/Format
Idle MTC Enabled
Window Burn options:
Variable Speed Offset
(VSO)
Default
01:00:00:00
AES/EBU
44.1 kHz
On
Off
Session (1x Word)
All
14–16
On (Enabled)
8 frames
+3 dBu
0000
Off
0100
A Lead B
NTSC
On
Enabled
Size: Large
Vertical Position: 20% from
Bottom
Horizontal Position: Center
Color: White on Black
background
Off