Getting the System Log via the Web Interface
Before starting the web interface, refer to steps 2 and 3 in "3-1-1. Firmware Update by Using WEB
Control", or refer to the operating instructions supplied with the PCS-XG Series models.
Open the web page and then select "Download" in the left column. Then, click "Download" to the right of
"Save System Log". Download of the system log starts.
Getting the System Log via the Serial Port
Use the MAINTENANCE connector (RS-232C, D-sub 9-pin) on the front panel of the main unit. (The
AUX CONTROL connector on the rear panel of the main unit cannot be used for taking a system log.)
For details on the communication confi guration settings for the software terminal (Hyper Terminal, for
example) on a PC which is connected to the MAINTENANCE connector on the main unit by a serial
crossover cable, refer to the fi gure below.
During operation, the system log is displayed on the software terminal connected through the serial cross-
ing cable.
VISCA OUT
TERMINAL
/
n
When obtaining the system log using the terminal software and a serial crossing cable, the entire system
log may not be collected.
3-24
Transfer rate: 115200 bps
Data length: 8 bits
STOP bit:
1 bit
Parity:
None
(Serial crossing cable)
MAINTENANCE
Terminal software
Personal computer
PCS-XG80