Table 6-2
Fault Symptom Codes
continued
2001
Ctl Invalid Command
2002
Undefined Config
2003
Invalid Drive State
2004
Loader Not Ready
2005
SCSI Id Not Set
2006
DLT Comm Open Error
2007
Door Fault
2008
Illegal Move
2009
Door Open
200A
Menu Mode
200C
Cart Unaccessible
200D
Drive In Error
200E
No Magazine
Diagnostics and Troubleshooting 6-9
Control Error Codes – 2xxx
Ctl. Invalid Command
An unsupported configuration was
detected.
One of the DLT drives was in an invalid
state This is caused by either
attempting to fetch a cartridge from an
empty drive, or stowing to a drive that
already has a cartridge loaded.
Currently not displayed.
An attempt to set the DLT SCSI id
failed.
An attempt to open a COM port failed.
An error occurred while attempting to
move the door.
While attempting to perform a MOVE
operation, the source or destination
locations were in the wrong state
(FULL or EMPTY).This also occurs if
the MOVE is attempted with an invalid
cartridge map.
A command was received while the
door was open.
A command was received while the
unit was in Menu mode.
An attempt was made to fetch a
cartridge from a drive that is not in the
unloaded state. This only applies
when the system is configured for
explicit unloads.
An attempt was made to access a
drive which is in an error state.
The element is not available because
the magazine is not installed.
continued