No Data Received Reports; Description; No Data Received; Data Error - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

Conettix D6600/D6100i | Installation and Operation Guide | 12.0 No Data Received Reports
.
Figure 15: Conettix Network System
Connection Diagram -
D9133TTL-E/DX4020 and Bosch
Control Panels
3
2
1
1 2 4 8
15
11
14
1 – Bosch Control Panels
2 – Connection – Control panel serial device
interface (SDI) bus to D9133TTL-E or DX4020
SDI Terminals
3 – D9133TTL-E or DX4020 Network Interface
Module
4 – Connection – D9133TTL-E or DX4020
Ethernet port to Ethernet hub
5 – Host PC running D6200 Programming
Administrative Software
6 – Connection – Ethernet hub to Host PC NIC
7 – Ethernet hub
8 - Connection – Ethernet hub to D6100i
9 - D6100i
10 – Connection – Ethernet hub to Network
Ethernet Module
11 – Network Ethernet Module
12 – Connection – Network Ethernet Module to
D6600 COM4 port
13 – D6600
14 – Connection – Second Network Ethernet
Module to D6600 COM1 port (optional)
15 – Connection – Ethernet hub to second Network
Ethernet Module
Bosch Security Systems, Inc. | 6/09 | 4998122704-06
4
5
6
7
10
9
12
11
13

12.0 No Data Received

Reports
12.1

Description

If a message is garbled (incorrect checksum or
inconsistent message rounds) due to a noisy
telephone line or other difficulty, the receiver
withholds the kiss-off tone. This causes the control
panel to send the same message again up to four
times.
12.2
No Data Received
The D6600/D6100i generates the message shown in
Figure 16 if one or more of the following events
occurs:
Telephone line noise causes the data to be
unrecognized.
A control panel sends the data in a format not
recognized by the D6600/D6100i.
A control panel transmitted nothing.
Figure 16: NO DATA RECEIVED Message

12.3 Data Error

Data Error is a function of PSTN. It is an error
condition when the D6600/D6100i receives partial
data, appears on the LCD, and sends the error to a
connected printer.
This occurs when telephone line noise causes data to
be unrecognizable.
12.4

Wrong Data

Wrong Data is a function of the CPU where the PSTN
software sends an invalid signal to the CPU. It only
sends output to the LCD and any connected printer.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100i

Table of Contents