Download Print this page

Installation Considerations; Installation Instructions - Bosch Conettix D6600 Installation Manual

Communications receiver/gateway card installation
Hide thumbs Also See for Conettix D6600:

Advertisement

D6600 | Card Installation Guide | 1.0
1.0
Introduction
These instructions describe how to install replacement or
upgrade cards in the Conettix D6600 Communication
Receiver/Gateway (D6600).
Bosch Security Systems
The D6600 provides eight line card slots
and one CPU card slot. Be sure to install
the cards in the correct slots. Refer to
Figure 2.
2.0

Installation Considerations

The D6600 provides eight line card slots, one
Conettix D6641 Telephone Line Card (D6641) and
one Conettix D6645 Telephone Line Terminator
Card (D6645) factory-installed combination (refer to
Figure 1 and Figure 2).
You must install a D6640 Telephone Line Card
(D6640) or a D6641 and a D6645 together.
For SafeCom applications:
You must install a Conettix D6690 SAFECOM Line
Card (D6690) and a Conettix D6695 SAFECOM
Line Terminator Card (D6695) together.
A Conettix D6691 SAFECOM Expansion Card
(D6691) provides an additional four channels for
locations that require more than four channels.
A D6690 with a D6691 requires two adjacent slots
and two D6695s.
3.0

Installation Instructions

If the door does not shut properly on any
card installation, check that the card is fully
seated.
Figure 1:
D6600 Front Panel
00/00 00:42
COMMUNICATIONS RECEIVER/GATEWAY
2
2
3
3
OL/LF
1
1
1 - Removable line card slot covers
2 - D6641 (factory installed)
3 - Door handle, secures with magnets
2
Introduction
1
2
3
A
B
4
5
6
C
D
7
8
9
E
F
M/E
CAN
POWER
SYSTEM TROUBLE
ACKNOWLEDGE
Figure 2:
D6600 Rear Panel
Bosch Security Systems
Fairport, NY
USA
1
1
B
A
T
T
E
R
Y
Input:
100 - 120/
220 - 240V~
50 - 60 Hz
2.5 Amps
1 - Conettix D6672 Com 1 Expansion Kit slot (opt)
2 - Conettix D6615 CPU Terminator Card slot
3 - Line termination slot covers
4 - Card slot screw (two per plate)
5 - D6645 (factory installed)
Figure 3:
D6600 Internal Front View
8
8
1
1
1
2
3
4
1 - D6641 (factory
installed)
2 - Plastic card guides
3 - Plastic tab for
installing or
removing CPU card
,
Refer to Figure 1
Figure 2, and Figure 3 in
3.2,
3.3
and
on pages 2 and 3 for instructions.
3.1
Termination Card Installation
To install the D6645 or D6695 Termination Card:
1. If you are installing a replacement termination card,
remove the old card:
a.
Open the D6600 front door and pull the
corresponding line card until it disconnects from
the termination card and the D6600 backplane.
b. Remove the two screws securing the old
termination card to the rear panel.
c.
Remove the old termination card.
2. If you are installing a new termination card, locate
the correct slot and remove the two screws securing
the blank plate to the rear panel.
Bosch Security Systems, Inc. | 2/07 | 4998141059-01
2
4
2
4
3
3
1
2
3
4
5
5
4
4
5
5
2
2
3
3
6
6
5
5
4
4
2
2
7
7
4 - Conettix D6610
CPU Line Card
(D6610)
5 - Ribbon cable tabs
6 - Ribbon cable
7 - LED enable cable
8 - D6600 backplane
Sections 3.1,