Selecting Program Options In The D6600/D6100Ipv6/D6100I - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 2.0 Making the Right Connection
.
Figure 6: Modem Cable Pin Definitions
1 - Data carrier detect (DCD)
2 - Receive (RX)
3 - Transmit (TX)
4 - Data terminal ready (DTR)
5 - Signal-ground (SIG-GND)
2.2

Selecting Program Options in the D6600/D6100IPv6/D6100i

Use the D6600/D6100IPv6/D6100i keypad or the D6200 Programming Software to program the
receivers. Below are the recommended selections for programming when connecting the receivers to
an automation system. Additional selections can be found in the D6600/D6100IPv6/D6100i Program
Entry Guide (P/N: 4998122702).
Table 1:
Recommended Programming Selections
Receiver
Selects a number (01 to 99) that is included in every message to the computer in
Gateway
both D6500 and SIA modes
Number
Output
Enable computer output messages in the selected format:
Format
SIA
D6500
Baud Rate
Use maximum speed supported by PC
Link Test
Tests if a supervision signal can be sent and received from the central station by
the receiver
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
1
2
3
6
7
computer interface standard format, recommended (expanded
reporting capabilities)
21-character format output
4
5
8
9
(Male DB9 on receiver)
6 - Data set ready (DSR)
7 - Ready to send (RTS)
8 - Clear to send (CTS)
9 - Ring indicator (RI)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6Conettix d6100i

Table of Contents