Mask off any areas of the active vacuum zone(s) that will not be occupied by the media.
2.
[72] Center Zone Valve (shown in the Off position)
Note:
The media can occupy more than one zone, but if a zone will be active, all of the area
not covered by the media must be masked so that all vacuum holes are covered.
If the Center Zone is not occupied by media it can be turned Off with the manual valve
located at the Zone 1 end of the printer.
Activate the zones you wish to use either with the icon on the command bar of the Print
3.
Job module or with the matched foot switch (1 or 2) on the floor.
Start the print job either with the Start icon on the command bar or with the Print Start
4.
button located near the vacuum gauges.
De-activate the zones with either the icon or the foot switch once the image is printed.
5.
Remove the media.