5-7. Image Setting Screen

This is to adjust composite and Y/C Video Signals.
Controls for brightness and Contrast are possible with all kinds of input signals.
Contrast:
Brightness:
Hue:
Chroma:
Blue only:
Video/S-Video Setup :
Filter select : This is to select filter of decoder. (Only for NTSC mode).
Edge enhancer:
IP mode:
This is to adjust the contrast, that is to control white level of
signals. (+)makes it brighter and (-) makes it darker.
This is to adjust the brightness, that is to control black level
of signals, (+) make it brighter, and (-) makes it darker.
This is to adjust colour phase, Hue.
This is to control the density of colour. (+) makes it stronger
and(-) makes it paler.
This turns the display to Blue colour only. This facilitates
adjustments for contrast, brightness, chroma, hue. But this
works only with an NTSC composite video input.
This is to select a video setup level for composite video, or
For Y/C signal input.
0 means the offset level is 0%.
Mid means the offset level is 3%.
Hi means the offset level is 7.5 %.
There are two kinds, 2D for 2 dimensional filter and 3D for 3
dimensional filter. Note that the factory default is 3D.
This is to control a sharpness of the picture.
(+) make it stronger and (-) makes it weaker.
This is to select a conversion mode of interlaced and progres-
sive scanning.
The Still mode is effective for still pictures and it is recom-
mended to use this Still mode for non-moving, still images.
The Motion mode is useful for moving picture and it is rec-
ommended to use this motion mode for moving pictures, es-
pecially fast motion.