to LP Gas (continued)
NOTE:
If an orifice
spud
is
accidentally
dropped,
the cooktop
can be raised by disengaging
the
2 front
clips with a large flat
blade screwdriver.
DO NOT attempt to raise the cooktop without
removing all 4 burner bases.
If wires were disconnected
to remove the cooktop,
feed
wires through
the burner
holes in the cooktop°
Attach
to each burner
electrode
terminal
carefully,
making
sure not to bend the termina!°
Then
lower cooktop
until
it snaps over the clips.
7. Carefully
insert
burner
bases
straight
down with
the tube over the
orifice
spud° Replace
the screws, making
sure the tall
screw is opposite
the burner
electrode
in each
burner
base°
B Standard
Twin Burner Models
(models with lift-up cooktops)
1. Lift the cooktop.
2. Lift the burner
assemblies
straight
up and
set aside to gain
access to surface
burner
spuds.
3. With
a 7 mm,
5/16"
or a small
"_[[_
adjustable
wrench
(depending
on the size needed),
remove
each
of the four spuds on the surface burner
gas inlet tubes
and replace them with the correct gas spuds mounted
in a holder
at the right rear of the range, above the
regulator.
Natural
gas spuds
are brass and LP gas
spuds are red or silver. (Mount
the spuds that you
removed
from
the inlet tubes back in the holder_)
To prevent
leakage,
make sure spuds are securely
screwed
into gas inlet tubes,
4. Replace the burner assemblies.
5. Keep all spuds with your
range so you have them
if
you move or get a different
gas hook-up
.... T op Bumer
Orifice Drill Size
Color
Natural Gas
#54 (.0550 Dia.)
Brass
Lp (Propane)
#66 (_0330 Dia.,)
Red or Silver
STEP
3
Convert
Oven
Thermostat
(for models
equipped
with Standing
Pilots)
1. Remove
the OVEN
CONTROL
knob°
2. Locate
the gas selector
screw at
the left of the thermostat
shaft.
Turn
the screw until
the small
pointer
stops at LP or N,
depending
on the type of gas you
are converting
to, The most the
screw will move is 1t2 a turn.
3. Replace
the OVEN
CONTROL
knob.
STEP
4
Convert
the Oven Burner
Orifice
2t
Remove
oven door, storage
drawer
or broiler
drawer
and oven bottom.
The lower burner
orifice spud is
located
behind
the storage
drawer,
broiler
drawer
or
kick panel.
(On some models,
a metal shield
must
be removed
to access the orifice.)
To convert
to LP gas, use a
I/2" wrench
to turn the lower
burner
orifice spud clockwise.
Tighten
the spud only until it is
snug. To prevent
damage,
do
not overtighten
the spud.
To convert
to natural
gas, loosen
the spud about
two turns,
42