Initialization And Adjustment; Tuning Initialization; Accessing Menus For Initialization And Adjustment; Adjusting Video Signal Level - Furuno FR-2125V Installation Manual

Furuno marine radar user manual
Hide thumbs Also See for FR-2125V:
Table of Contents

Advertisement

INITIALIZATION AND ADJUSTMENT

3.1 Tuning Initialization

Tune the radar as follows: Press [RADAR MENU] [0] [0] [2] [0] [0] [0] (TUNE
INITIALIZE on the RADAR 3 menu) and press the [ENTER] key.

3.2 Accessing Menus for Initialization and Adjustment

To access them do the following:
1. Turn on the power.
2. Press the [RADAR MENU] key five times while pressing and holding down
the [HL OFF] key. A beep sounds to confirm operation.
Restoring default settings
1. Press [RADAR MENU] [0] [0] [0] [2] [0] [0] [0] to display the INITIAL SETTING
4 menu.
2. Press the [0] key to select FACTORY DEFAULT.
3. Press the [ENTER] key five times, and turn the power off and on again.
4. "Initializing" appears during restoring. It takes about 90 seconds to restore the
default settings, after which the normal display appears.

3.3 Adjusting Video Signal Level

When the signal cable is very long, the video amplifier input level decreases,
shrinking target echoes. To prevent this, confirm (and adjust if necessary) video
amplifier input level.
1. Connect an oscilloscope to TP6 on the INT Board (03P9252) in the display
unit.
2. Transmit on the 12 nm range.
3. Adjust R21 on the INT Board so the value of TP6 is 4 Vpp. (For remote dis-
play, adjust R134 on the INT Board.)
Figure 3-1 Display pedestal
3-1
TP1
TP6
R21
INT Board
(03P9252)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents