7. Attach instruction label (supplied) to shield cover for the INT and GYRO CON-
VERTER boards.
8. Close the monitor.
9. Turn the power off and on again to reset the CPU.
Connection of external power supply
An external power supply is necessary when the repeater signal is step-by-step
type and the step voltage is below 20 V or output voltage is less than 5 W.
1. Cut the jumper wire JP1 on the GYRO CONVERTER Board when an external
power supply is used.
2. Connect the gyro cable and power cable as shown below.
External Power Supply
20 - 135 VAC
20 - 100 VDC
Gyrocompass
(Step type)
Figure 4-3 Connection of external power supply to GYRO CONVERTER Board
DIP switch, jumper wire settings
Default setting
The default setting of all DIP switches is off and all jumpers wire are set to "#1."
(Note that the jumper wire JP1 is set at #1, #2, and #3.) In those settings the
gyrocompass having the following characteristics can be directly connected; modi-
fication of the GYRO CONVERTER Board is not necessary.
AC synchronous signal: 50/60 Hz
Rotor voltage: 60 V to 135 V AC
Stator voltage: 60 V to 135 V AC
Gear ratio: 360X
Supply voltage: 30 V to 135 V AC
GYRO CONVERTER Board
[A] 64P1106
1 R2
2 R1/COM
Either connection
in case of DC
polarity.
S1
1S1
S2
2 S2
S3
3 S3
COM
4 T
F.G.
5 F.G.
4-3
J5
J4

Hide quick links: