Operation, Storage and Transportation
Requirements
Operation requirement
Temperature
Humidity
Shelf time
Storage requirement
Temperature
Humidity
Storage condition
Transportation requirement
Temperature
Humidity
Temperature gradient
Transportation condition : Store an AIT data cartridge in a protective case. During transporta-

Label

It is recommended that you should affix a label to each AIT cartridge to associate the AIT data
cartridge with the backup data for easier identification.

Label paste position

30 AIT Data Cartridge
: 5 to 45 C
: 20 to 80 % (The maximum temperature of wet bulb is 26 C.)
: If an AIT data cartridge is exposed to an environment other than
the operating or storage environment, expose it to the operating
environment for a longer time than the period when it is exposed to
other environment (for 8 hours at maximum) before use. The
temperature gradient is 10 C/hour.
: 5 to 32 C
: 20 to 60 % (The maximum temperature of wet bulb is 26 C.)
: Store an AIT data cartridge in a protective case with cover. You
can place the case horizontally or vertically.
: -40 to 45 C
: 5 to 80 % (The maximum temperature of wet bulb is 26 C.)
: 10 C/hour
tion, pack the case so that force will not apply to the AIT data
cartridge.