Setting The Built-In Ait Auto-Loader Unit; Setting With The Dip Switch - NEC N8551-29F Instruction Manual

Built-in ait auto-loader unit
Table of Contents

Advertisement

Setting the parity function
Set the parity function using the leftmost jumper pin on the rear of the Built-In AIT Auto-Loader
Unit.
The parity function is "Enabled" when setting "Without strap" (factory-set value). The parity
function is "Disabled" when setting "With strap".
Important
To improve reliability, set the parity function "Enabled" (Without strap).

Setting the Built-In AIT Auto-Loader Unit

The DIP switch on the bottom of the Built-In AIT Auto-Loader Unit enables you to change the
following settings.
• Terminator Power (Terminator power supply) (Factory-set to ON)
• DC Control (1) (Data compression setting) (Factory-set to ON)
• DC Control (2) (Data compression setting) (Factory-set to OFF)
6
Built-In AIT Auto-Loader Unit
PD (Factory-set to "Without strap")

- Setting with the DIP switch -

ON
1 2 3 4 5 6 7 8
Switches 1 to 4: Unused
Switch 5: Terminator Power
Switch 6: Unused
Switch 7: DC Control (1)
Switch 8: DC Control (2)

Advertisement