Dell PowerConnect J-8208 Release Note page 48

Release notes junos version 10.3
Hide thumbs Also See for PowerConnect J-8208:
Table of Contents

Advertisement

Junos 10.3 OS Release Notes
48
J-SRX240 Services Gateway Hardware Guide
The output for the
show chassis hardware
is incorrectly documented for the Routing Engine field. The following table provides
details of the guide, section, incorrect output, and corrected output for these commands.
Section
Monitoring the J-SRX240 Services
Gateway Chassis Using the CLI
Locating the J-SRX240 Services
Gateway Component Serial Number
and Agency Labels
The "Understanding Built-In Ethernet Ports" section in the J-SRX240 Services Gateway
Hardware Guide erroneously states the following:
The services gateway acts as a DHCP client out of the built-in Ethernet ports. If the
services gateway does not find a DHCP server within a few seconds, the device acts
as a DHCP server and assigns an IP address as 192.168.1.1/24. With the device
temporarily acting as a DHCP server, you can manually configure it with the J-Web
interface.
The correct information for this section is as follows: The services gateway acts as a
DHCP client on port ge-0/0/0, and ports ge-0/0/1 to ge-0/0/15 act as a DHCP server.
The "J-SRX240 Services Gateway (High Memory with DC Power Supply Model)
Compliance Statements for Network Equipment Building System (NEBS)" section in
the J-SRX240 Services Gateway Hardware Guide incorrectly states that the battery
return connection is to be treated as a Common DC return (DC-C), as defined in
GR-1089-CORE.
The guide should state that the battery return connection is to be treated as an Isolated
DC return (DC-I), as defined in GR-1089-CORE.
The J-SRX240 Services Gateway Hardware Guide is missing information about the
following statements and data:
The "J-SRX240 Services Gateway Site Electrical Wiring Guidelines" section should
include the following statement:
For devices with AC power supplies, an external surge protective device (SPD) must
be used at the AC power source.
The "General Electrical Safety Guidelines and Warnings" section should include the
following statements:
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
and
show chassis hardware detail
Incorrect Value in the
Correct Value Displayed
Hardware Guide
in the Command Output
RE-J-SRX240-LM
RE-J-SRX240B
RE-J-SRX240-POE
RE-J-SRX240H-POE
commands