Allocate function of each current sensor:
KPT 1 = 1
KPT 2 = 1
Allocate mains state inputs for each current sensor:
Note: Input numbers 1 to 32 on the buffered input connector are referenced as 0
to 31 on the handset commands.
KMS 0 1 = 31
KMS 0 2 = 30
Allocate phase identity to each current sensor:
KAD 1 = 0
KAD 2 = 1
Select normal lamp monitoring (not RLM) on vehicle phases:
KRE 1 = 0
KRE 2 = 0
Reset the lamp monitor and enable lamp monitoring:
KLR = 1
KLE = 1
Example 2 - 4 phase controller with signs
Description: Four phase intersection controller with no lamp dimming. Two of
The configuration commands are detailed below.
Enable LMU write access:
AMB = 35
NEC = 249
Allocate function of current sensor 1 to 9:
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
:current sensor 1 monitors a vehicle phase
:current sensor 2 monitors a vehicle phase
:mains state for sensor 1 is on
:digital input 32
:mains state for sensor 2 is on
:digital input 31
:sensor 1 is phase A
:sensor 2 is phase B
:sensor 1
:sensor 2
:reset lamp characteristics
:enable lamp monitoring
the phases are vehicle and two are pedestrian. The controller also
drives regulatory signs and two switched signs.
The wait indicators in this example are monitored using their own
current sensors, separately from those used to monitor the
pedestrian red and green (see example 3 for combined wait and
pedestrian monitoring on one current sensor).
Page 120
Issue 10