3.3.3.37 Mains states input configuration (KMS) L
KMS {mains state input: 0-2 }{ sensor: 1 - 23 }= Input line number: {0 - 31} (255)
This item defines the digital inputs that provide the mains state(s) for the
associated current sensor. Up to three input line numbers are required depending
on the phase type being monitored (see table below).
The following is a list of the lamp mains state entries required for the different
phase types that the current sensors can monitor. If no mains state is required
enter the default value of 255.
Monitored Phase Type
IV
IVRLM
IP
PV
PP
PPW
PS
IPW
IPS
XP1
XV1
XV2
XV3
W4
W6
RS
SB
ST
In addition, for PB392 Firmware:
PP4
PS4
IP4
IS4
Note The 32 inputs are numbered 1 to 32 in section 3.2.3.5, corresponding to
the associated pin on the 40 way input connector, however the handset
command numbers the inputs from 0 to 31, for the 32 inputs.
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
1st entry
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
VEH. GREEN
GREEN
VEH. GREEN
RED
GREEN
BALL
GREEN
WAIT
WAIT
-
SIGN
SIGN
GREEN
VEH GREEN
PED GREEN
VEH GREEN
Page 106
2nd entry
3rd entry
-
RED
VEH. GREEN
PED. GREEN
-
WAIT
PED. GREEN
WAIT
VEH. GREEN
WAIT
PED. GREEN
WAIT
-
-
-
AMBER
-
-
-
-
-
WAIT
PED GREEN
VEH GREEN
PED GREEN
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WAIT
WAIT
WAIT