3.3.3.28 Display Fault Data (GLD)
GLD (Fault data index : 0 - 227)
Comment:
Fault data index 0 - 215 Lamp Fault Data (Fault flags 0 - 3 Lamp Faults)
If the KLP command is supported this information is also available using KLP.
The data for each current sensor is as follows:
Offset from starting index
0
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
The data in the log is generally indicated against aspect pattern number as
follows:
Aspect Pattern No
0
1
2
- for Export lamp sequences the following pattern numbers are used:
1
3
The following monitor types can record a fault in more than one aspect pattern
number for failure of one colour. The aspect number where the failure is actually
logged will depend on which aspects were showing at the time of the failure.
Monitor type
- UK Pelican and Intersection Ped. Including wait
UK Pelican and Intersection Ped. Stream
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
To examine fault data associated with certain fault flags
Phase identification 0 = A, 1 = B etc
Number of current rises / Lamp failures - aspect pattern 0. Rises
in high 4 bits - failures in low 4 bits
Rise/fail counts - aspect pattern 1
Rise/fail counts - aspect pattern 2
Rise/fail counts - aspect pattern 3
Rise/fail counts - aspect pattern 4
Rise/fail counts - aspect pattern 5
Rise/fail counts - aspect pattern 6
Lamp Colour
Red (R) or Red Man (Rm)
Green (G), Green Man (Gm), Wait (Wt) or Sign (S)
Amber (A)
Flashing Amber Ball (FL.B) (for XV2 type)
Flashing Amber (FL.A) (for XV3 type)
Page 99
Failed Colour
Pattern No.
Rm
0 if Wt off
2 if Wt on
Wt
2
Gm
1
R
3
A
1
G
2
Rm
1 if A on
2 if G on
Wt
5 if A on
6 if G on
Gm
3