6 Electrical installation

6.8.2 Connecting further mixer circuits

Like the VR 90 remote control units, the VR 60 mixer
modules also communicate with the heating controller
via the eBUS. When installing, observe the same proce-
dure as for connecting the remote control units (see
Chap. 5.8.1).
The system structure can be seen in Fig. 5.16. Observe
the mixer module manual.
Fig. 6.16 Connecting further mixer circuits

6.8.3 Connecting vrnetDIALOG

The vrnetDIALOG communications unit (accessory) is
fastened to the mounting plate provided on the frame
of the operating console and connected to the control-
ler PCB.
Fig. 6.17 Fitting vrnetDIALOG
38
6
5
4
3
Fig. 6.18 Connecting vrnetDIALOG
• Fasten the casing of the vrnetDIALOG to the mounting
panel of the operating console using the self-tapping
screws (1) and (2) from the accessory bag. For fixing,
see also the vrnetDIALOG manual.
• Pass the power supply cable present within the heat
pump (5) through the opening in the upper front clad-
ding and connect it to the vrnetDIALOG unit.
• Next pass the connecting cable (6) from the operating
console through the opening in the upper front clad-
ding and connect to it the adapter cable from the ac-
cessory pack (4) for connecting between the vrnetDI-
ALOG unit and the heat pump.
The connector on the adapter cable is intended for the
operating console; the second cable is intended for con-
nection to the eBUS plug from the vrnetDIALOG unit.
h
Note!
Any other eBUS cables already present
on the vrnetDIALOG unit are not re-
quired and can thus be removed.
• Now connect the aerial or telephone cable (3) to the
vrnetDIALOG unit (see also the vrnetDIALOG manual).
These cables must not be fed through the heat pump.
Installation instructions geoTHERM VWS 0020046310_01