6 Electrical installation
6.4.1

Unblocked mains supply (Electroplan 1)

A1
L1
Fig. 6.2 Unblocked mains feed (supplied configuration)
This is how the heat pump is wired when delivered.
The heat pump is connected to the mains on a single ta-
riff (one consumer meter) (1). The power company re-
serves the right to switch off the compressor and the
auxiliary heating as required by means of a ripple cont-
rol signal. The duration and frequency of the deactivati-
on is determined by, or must be arranged with, the
power company.
Key to Fig. 6.2
:
2 kW
:
4 kW
26
1
+
230 V / 50 Hz
PE N
A2
L2
L3
N
ABB
A12-30-01
T1
T2
T3
Pump
Compressor
Controller
Auxiliary heater
You can set the output of the
auxiliary heating from 4 kW to
2 kW by removing the bypass line,
if required.
+
+
L
L
N
L
N N
L
L
• Connect the power supply to the principal mains feed.
• Connect the ripple control signal relay to terminal 13
"EVU", if required by the power company. This signal
blocks the heat pump when the contact is closed (see
Fig. 6.7).
You will find an overview of the complete wiring dia-
gram in the appendix.
:
2 kW
:
4 kW
S S B B A Z N
L
N
L L
Installation instructions geoTHERM VWS 0020046310_01