7.3

Carrying out the initial commissioning

As soon as the heat pump is supplied with power during
the initial commissioning, an internal self-test starts au-
tomatically, whereby the heat pump checks itself and
any connected components for functional capability.
The sensor pin assignment is also checked during the
self-test and also the sensors used to make sure they
are in working order.
If the self-test was not successful, an error message ap-
pears on the controller display (see Chap. 10, "Trouble-
shooting and diagnosis").
• Switch on the circuit breaker, so that the heat pump is
supplied with power.
The heat pump starts, the controller software is initiali-
sed:
Vaillant
Loading...
Fig. 7.2 Controller being initialised
After a short time the controller is ready for operation
and detects that this is an initial commissioning. During
the initial installation the controller always starts with
the Installation Assistant - Menu A1.
Installation
Language selection
Language
>Select
Fig. 7.3 Menu A1: Language selection
Installation instructions geoTHERM VWS 0020046310_01
A1
>GB English
Change the language setting if necessary and turn the
dial to the next menu.
Installation assistant
Hydraulic scheme
Electric Wiring Diagram
Accept change
>Select
Fig. 7.4 Menu A2: Installation assistant
h
The heat pump type has already been
set at the factory and may not be chan-
ged!
Selecting the hydraulic plan
a
Caution!
Possible malfunctions.
Take care to select the correct hydraulic
plan, as otherwise malfunctions can
occur in the system.
• Turn the
dial until the cursor > points to the hydrau-
lic plan no.
• Press the
dial. The parameter will be activated and
displayed in inverse video.
• Turn the
dial until the hydraulic plan matching your
system has been selected (see Table 7.1).
You will find the hydraulic diagram for your installati-
on in Chap. 6.7.2 ff.
• Press the
dial to confirm the selection.
1
X
2
X
X
3
X
X
4
X
X
X
Table 7.1 Selecting the Hydraulic plan No.
Selecting the electroplan
• Turn the
dial until the cursor > points to the number
of the electroplan.
• Press the
dial. The parameter will be activated and
displayed in inverse video.
• Select
Start-up 7
A2
0
0
No
AF, VF2
AF, VF1, VF2, RF1
AF, SP, VF2
AF, SP, VF1, VF2, RF1
6.8
6.9
6.10
6.11
43