Dual Circuit Feed, Heat Pump Tariff (Electroplan 2) - Vaillant geoTHERM VWS Installation Instructions Manual

Hide thumbs Also See for geoTHERM VWS:
Table of Contents

Advertisement

6.4.2 Dual circuit feed, heat pump tariff
(Electroplan 2)
A1
L1
Fig. 6.3 Dual circuit feed, heat pump tariff
In this instance the heat pump is operated on two tariffs
(two consumer meters). A permanent supply (2) for the
secondary consumers (auxiliary heating, circulation
pumps, controller, etc.) must be ensured via a meter.
The low tariff supply (1) for the compressor is effected
via a second meter and can be interrupted by the power
company at peak times.
Key to Fig. 6.3
:
2 kW
:
4 kW
Installation instructions geoTHERM VWS 0020046310_01
1
230 V / 50 Hz
PE N
A2
L2
L3
N
ABB
A12-30-01
T1
T2
T3
Pump
Compressor
Controller
Auxiliary heater
You can set the output of the
auxiliary heating from 4 kW to
2 kW by removing the bypass line,
if required.
2
+
230 V / 50 Hz
N
L
PE
L
3
L
N
L
N N
L
L
• Remove the jumpers (dashed lines, 3).
• Connect the permanent power supply to the high ta-
riff mains feed (2).
• Connect the low tariff power supply to the low tariff
mains feed (1).
• Connect the ripple control signal relay to terminal 13
"EVU", if required by the power company. This signal
blocks the heat pump when the contact is closed (see
Fig. 6.7).
You will find an overview of the complete wiring dia-
gram in the appendix.
Electrical installation 6
+
:
2 kW
:
4 kW
S S B B A Z N
L
N
L L
27

Advertisement

Table of Contents
loading

Table of Contents