E Basic Hydraulic Diagram; F Heat Pump Output Curves - Vaillant aroSTOR VWL BM 270/5 Installation And Maintenance Instructions Manual

Hide thumbs Also See for aroSTOR VWL BM 270/5:
Table of Contents

Advertisement

E
Basic hydraulic diagram
Validity: aroSTOR VWL BM 200/5, aroSTOR VWL BM 270/5
Note
All of the valves and connections that are integrated into the system must have a nominal operating pressure of
0.6 MPa (6 bar) or higher.
7
1
16
1
Dielectrically isolated hydraulic connection
2
Stopcock
3
Circulation pump
4
Non-return valve
5
Stopcock
6
Thermostatic mixer tap
7
Circulation pump
8
Expansion relief valve
9
Expansion vessel
10
Safety assembly
F
Heat pump output curves
B
4.5
4
1
3,5
3
2,5
2
1,5
1
0,5
0
-10
0
10
A
Air temperature in °C
B
Working figure (COP)
1
COP at a cold water temperature of 10 °C for a tar-
get temperature of 55 °C (EN 16147:2017/extraction
cycle L)
0020290840_00 aroSTOR Installation and maintenance instructions
6
2
3
4
5
8
9
10
14
11
13
12
15
00:00
21:00
18:00
15:00
12:00
2
09:00
6:00
3:00
00:00
20
30
40
17
18
19
11
Stopcock
12
Pressure reducer
13
Non-return valve
14
Stopcock
15
Expansion vessel
16
Drain valve
17
Domestic hot water flow
18
Hot water circulation
19
Cold water pipe
A
2
Heating time at a water temperature of 10 °C for a
target temperature of 55 °C (EN 16147:2017/extrac-
tion cycle L)
Appendix
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arostor vwl bm 200/500100268180010026819