Destination Selection - FOLSOM ScreenPRO FC-0608 Installation And Operator's Manual

Multi-screen remote
Table of Contents

Advertisement

Destination Selection

Certain commands listed below require the selection of Screen and/or AUX destinations. The operand will be listed in
the command as "dddd". This represents a maximum of 4 hexadecimal digits, which is a 16-bit value. While this is
what the operand represents, the operand must be embedded into the command string as standard ASCII
characters. The bits map to the Screens and AUXs as shown in the figure below.
Destination Bus for FC-0616
Screen
Screen
Screen
1
2
3
Bit 0
Bit 1
Bit 2
Destination Bus for FC-0608
Screen
Screen
Screen
1
2
3
Bit 0
Bit 1
Bit 2
To select a destination, place a 1 in the bit location that corresponds to the Screen or AUX you wish to use. Place a 0
in all other bit locations. Once you have the binary bit string, convert this binary value to a hexadecimal value. Use
this value in the command where "dddd" is specified.
NOTE: Some bits are ignored as shown in the examples below. Place a 0 in these locations.
Manual #26-0111200-00 / Revision E
Screen
Screen
Screen
6
AUX 2
4
5
AUX 1
Bit 3
Bit 4
Bit 5
Bit 6
Screen
Screen
Screen
All
4
5
6
Bit 3
Bit 4
Bit 5
Bit 6
Ignored
Bit Mapping for FC-0616 & FC-0608 Destination Bus
BINARY
b
b
b
b
3
2
1
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
Binary to Hex Conversion Table
AUX 3
AUX 4
AUX 5
AUX 6
Bit 7
Bit 8
Bit 9
Bit 10
Clear
Bit 7
Ignored
HEX
0
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ScreenPro Multi-Screen Remote
AUX 7
AUX 8
AUX 9
AUX 10
Bit 11
Bit 12
Bit 13
Bit 14
Clear
Bit 15
Ignored