EP cylinder dwell time
– Dwell time for the EP cylinder
In the extended menu:
Call up the APT1 function.
Set the desired value.
– Settings are possible in 1 ms steps:
1 ... 7500 ms
Confirm the setting using the ENTER key and exit
the function.
Blowing time
When using a blowing applicator:
– Dwell time for blowing the label on the product
In the extended menu:
Call up the APT2 function.
Set the desired value.
– Settings are possible in 1 ms steps:
1 ... 7500 ms
Confirm the setting using the ENTER key and exit
the function.
Delay time
When using an EP applicator:
– Delay of the signal air blow.
The signal controls the air blow which blows the la-
bel onto the underside of the applicator. The value
for APT3 is the delay between the start of label dis-
pensing and activation of the air blow.
In the extended menu:
Call up the APT3 function.
Set the desired value.
– Settings are possible in 1 ms steps:
1 ... 5000 ms
Confirm the setting using the ENTER key and exit
the function.
(
)
OPTIONAL
(APT1)
(APT2)
(APT3)