Avery Dennison ALS 350 User Manual page 94

Label dispenser
Table of Contents

Advertisement

6
O
PERATIONAL MALFUNCTIONS
6.2 E
RROR MESSAGES
Message
Description
E_14
Too many products between product
sensor and dispensing edge.
E_15
Short circuit
or
Overload of outputs from CN10
ER-U
Software error
ER-I
Software error
ER-D
Software error
ER-T
Software error
ER-A
Software error
Possible causes and remedies
Product sensor located too far from dispensing edge:
– A maximum of 7 products can be located between
the product sensor and the dispensing edge.
Change the position of the product sensor.
Subsequently correct the POS setting.
The product triggers several start signals, caused by
reflections, for example:
Adjust the product length (PRDL function).
A check of the connections and output signals by
servicing technicians is required; refer to the service
guide.
Press the ENTER key.
Make note of all the information that is displayed on the
control panel.
Make note of what happened before the error occurred.
Inform Avery Dennison's customer service.
94