4.1 A
CTIVATION AND SHUT

Unwind unit

– A loop forms in the loop space as a buffer between
the unwind unit and label dispensing,
ALS 350: [44 arrow], ALS 450: [45 arrow].
– A photoelectric sensor in the loop space monitors
the loop.
– If the loop becomes too large, the control system au-
tomatically slows the unwinding speed. The dis-
pensing speed does not change.
– ALS 450: The dancer arm swings approximately into
the centre position [45B].

Rewind unit

– The multiple deflections with the spring-loaded
dancer arm act as a buffer between the label output
and the rewind unit. During operation, the dancer
arm swings between the horizontal and its upper
end limit,
ALS 350: [44A], ALS 450: [45A].
– If necessary, the control system automatically slows
the rewinding speed. The dispensing speed is not
affected by this.

Stop/end the label dispensing

4.1.3
Press the ENTER key.
– The unwind unit, dispenser drive, and rewinding unit
shut down.
– „OFF" appears on the operator panel [46].
– Start signals from the product sensor are ignored.
-
DOWN
[44] ALS 350 in labelling mode
B
[45] ALS 450 in labelling mode
[46] OFF display on the operator panel