6
O
PERATIONAL MALFUNCTIONS
6.2 E
RROR MESSAGES
Message
Description
E__7
Photoelectric sensor in the loop
space does not detect the loop for-
mation; label stop sensor does not
detect the labels and problem with
the rewind unit.
E_10
Error at applicator
E_11
Many products are not labelled. The
number of unlabelled products is
greater than the amount set in the
MLAB function.
E_12
Invalid setting value Factory settings
are activated, see Appendix.
E_13
Label roll is completely consumed.
Labels are no longer detected at the
label stop sensor.
Possible causes and remedies
Refer to E__1, E__2, and E__4.
When using an EP applicator:
The applicator must be checked by servicing techni-
cians.
The distance between the products on the conveyor
belt is insufficient:
Increase the product distance.
For circumferential labelling: Increase the rotational
speed.
The product triggers several start signals, caused by
reflections, for example:
Adjust the product length (PRDL function).
When using a printer, the printing time is too long:
If possible, decrease the printer dwell time (PDWT
function).
Start printing process before label stop (PDT func-
tion).
Several labels are missing from the label ribbon:
Replace label roll
or
Increase value for MLAB, if possible.
Erroneous settings in the extended menu:
Check the POS2 and POS3 settings.
A serious memory error has occurred:
– The control system needs to be reconfigured by a
servicing technician or the customer service; refer
to the service guide.
Replace label roll.
93