PERATIONAL MALFUNCTIONS
6.2 E
RROR MESSAGES
Message
Description
E__2
Label stop sensor does not detect
the labels.
E__3
The photoelectric sensor in the loop
space does not detect the loop for-
mation and the label stop sensor
does not detect the labels.
E__4
Rewind unit problems
E__5
Photoelectric sensor in the loop
space does not detect the loop for-
mation and problem with the rewind-
ing unit.
E__6
Label stop sensor does not detect
the labels and problem with the re-
wind unit.
Possible causes and remedies
Ribbon of labels does not run through the slot in the photoe-
lectric sensor:
Check the ribbon guide at the label stop sensor.
Label roll empty or more than 3 labels missing:
Replace label roll as required.
Pressure roller not closed:
Swing back the lower pressure roller and return it to its
position pressing against the feed roller unit. The pres-
sure roller clicks neatly into its operating position.
Insufficient labelling speed:
– The product pulls the label off of the base material.
Synchronise the labelling speed and product speed
(VELO function).
Other options:
Manually adjust the sensitivity of the label stop
sensor (CONT).
Check the label stop position (STOD).
Check the label distance setting (LPIT).
Check to see whether the feed motor behind the
dispenser head is running.
Refer to E__1 and E__2; First check the loop formation.
Label roll empty:
Replace label roll.
Label ribbon torn:
Rethread the label ribbon at the rewind unit.
Rewinding motor runs too slowly or is defective:
– Setting or adjustment by servicingtechnician is re-
quired; refer to the service guide
Refer to E__1 and E__4.
Label ribbon torn:
Rethread the label ribbon at the rewind unit.