Avery Dennison ALS 350 User Manual page 90

Label dispenser
Table of Contents

Advertisement

6
O
PERATIONAL MALFUNCTIONS
6.1 W
ARNING MESSAGES
Message
Description
W__2
Memory errors
Factory settings are activated, see
Appendix.
W__3
Too many labels between label stop
sensor and dispensing edge.
W__4
Dispensing speed is too high.
This negatively affects position
accuracy.
W__5
The roll diameter control (optional)
reports the end of the label roll.
W__6
Data transmission error at the V24
interface
W__7
Label position on the product too
close to the product's leading edge
and high dispensing speed
Possible causes and remedies
CPU battery is discharged after a long shut-down period of
the machine:
Leave the machine switched on for some time to re-
charge the battery
If the accumulatorerror occurs frequently:
Have the CPU battery replaced by the customer
service.
Settings no longer available after software update.
Settings must be input again by a servicing techni-
cian; refer to service guide.
Label stop sensor must be adjusted by servicing
technician; refer to service guide.
Reduce dispensing speed (VELO), if the warning-
message is frequently displayed for long periods.
For automatic dispensing speed (APSF):
A check of the EGRA function is required
Insert new labelling material.
The cables, plug connections, and interface param-
eters must be checked by servicing technicians; re-
fer to service guide
Increase the setting value for POS, decrease dispensing
speed (VELO).
If this is not possible or the warning message
reappears:
The settings in the configuration menu must be
checked by servicing technicians; refer to service
guide.