Fine Tuning Of The Dwell Time (Apt4) - Avery Dennison ALS 350 User Manual

Label dispenser
Table of Contents

Advertisement

4
O
PERATION
4.6 A
PPLICATOR
Fine tuning of the dwell time
When using an applicator in combination with the auto-
matic speed adjustment (APSF):
– Optimise the accuracy of the label position on the
product by fine tuning the dwell time for the applica-
tor.
Standard values:
– Blowing applicators: approx. 25 ms
– EP applicators: 60 ms ... 100 ms, depending on the
length of the stroke
Prerequisite:
– External RPM transmitter is calibrated (EGRA func-
tion)
Determining and setting the exact value [88]:
Call up the APT4 function in the extended menu.
Set the setting value for APT4 to 1.
Allow the conveyor belt (with products) to run slowly.
– Speed v
= 10 m/min
N
Document the position of the label on the product:
Value: POS
in mm
N
Increase speed of the conveyor belt to approx.
25 m/min (value v
).
H
Document the position of the label on the product:
Value: POS
in mm
H
Calculating the setting value for APT4:
Input the calculated setting value.
Confirm the value using the ENTER key and exit the
function.
Test the setting:
Test the labelling accuracy at different conveyor belt
speeds.
If necessary, correct the setting value for APT4:
– The greater the value for APT4, the farther forward
the label is applied.
– The smaller the value for APT4, the farther to the
rear the label is applied.
(
)
OPTIONAL
(APT4)
85
[88] Label position in relation to the conveyor belt speed
v
- Low conveyor belt speed
N
POS
- Label position at lower conveyor belt speed
N
v
- High conveyor belt speed
H
POS
- Label position at higher conveyor belt speed
N
ALS
350
450

Advertisement

Table of Contents
loading

Table of Contents