4.4 S
ETTINGS IN THE EXTENDED MENU
Distance from the label stop
4.4.8
sensor to the dispensing edge
(E–SS)
– Correct specification of the distance between the la-
bel stop sensor and the dispensing edge is a prereq-
uisite for setting the label stop position (STOD).

Set distance

Adjust the distance between the label stop sensor
and dispensing edge Round the measured value up
to a whole number value in mm.
In the extended menu:
Call up the E–SS function.
Input the distance value.
– Settings are possible in 1 mm steps:
Minimum: 12 mm
Maximum: 1000 mm
– A maximum of 15 labels can be located between the
photoelectric sensor and the dispensing edge.
Confirm the value using the ENTER key and exit the
function.
Check setting (see next page).
The minimum setting depends on the dispens-
ing speed.
– The greater the dispensing speed, the great-
er the minimum distance.
– If the minimum distance is not maintained,
the warning message W__7 appears.
[77] A Distance between the label stop sensor and dispensing edge