amlog(1M)
RAW OUTPUT FORMAT
The contents of the raw output text string for log entries is as follows:
Default Log Output
AL:LogFilename:AddSenAvailable:SenseDate:SenseTime:FRUCode:
FRUCodeQual:SK:ASC:ASCQ:ArrayID:LogDate:LogTime:LUN
a
One record will be printed for each log entry between the start and end times.
LogFilename is the name of the server log file where the record is found.
The leading
AddSenAvailable is a boolean that indicates whether the SenseDate, SenseTime and FRUCodeQual are
available from the SCSI sense data that generates these fields. If FALSE (0), these fields will be undefined.
SenseDate and SenseTime correspond to the time of the reported event, while LogDate and LogTime
correspond to the time when the event was written to the log file. The format of the SenseDate is
MMDDYY, while that of LogDate is MMDDYYYY. The format for the SenseTime and LogTime is
HHMMSS.
The SCSI sense data fields, FRUCode, SK, ASC,ASCQ, are one byte hexadecimal; the FRUCodeQual field
is two bytes hexadecimal.
The LUN field will be appended to the output only if the LUN information in the sense data is valid.
Major Event Log Output
AM:LogFilename:ArrayID:LogMonth:LogDay:LogYear:LogHour:LogMin:
LogSec:SeqNum:EventType:EventMonth:EventDay:EventYear:
EventHour:EventMin:EventSec:EventCategory:CompType:
LocationValid:CompLocation:EventPriority:SK:ASC:ASCQ:FRUCode:
FRUCodeQual:LUN
One record will be printed for each log entry between the start and end times.
LogFilename is the name of the server log file where the record is found.
The leading
The Log* timestamp indicates when this event was written to the log file.
The Event* timestamp indicates when this event occurred.
LocationValid is a boolean that indicates whether the CompLocation field is valid.
If LocationValid is TRUE (1), CompLocation indicates an enclosure and, if applicable, a slot. Otherwise,
this field is undefined. If both an enclosure and slot are indicated, they will be separated by a comma. The
CompType field determines whether the CompLocation field will include a slot number.
SK, ASC, and ASCQ are SCSI sense data, each one byte hexadecimal.
If
is specified, only MEL events with an EventPriority of CRITICAL will be displayed.
-c
The final three fields (FRUCode, FRUCodeQual, and LUN) are only displayed if the EventType is 0x3101
(Asynchronous Event Notification or
cimal, respectively. The LUN field is only displayed if valid LUN information is available in the AEN sense
data.
DEPENDENCIES
There are no dependencies for this command.
AUTHOR
was developed by HP.
amlog
SEE ALSO
amdsp(1M), amcfg(1M), amutil(1M), ammgr(1M), AM60Srvr(1M).
58
Hewlett-Packard Company
is literal, and identifies this as an AM60 LOG record.
AL
is literal, and identifies this as an AM60 LOG record.
AM
AEN
). FRUCode and FRUCodeQual are one and two bytes hexade-
− 3 −
HP-UX 11i Version 2: December 2007 Update
amlog(1M)