Chapter 7 Troubleshooting
7.1 Check List
2
3
4
5
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Change the status of the ETERNUS DX Disk storage system to maintenance
status.
Use the pin that is provided with the ETERNUS DX Disk storage system to push down the
FUNCTION button for three seconds.
The ETERNUS DX Disk storage system is in maintenance status when the MAINT/ID LED
is green.
Use the pin to push down the FUNCTION button three times within three sec-
onds.
After the default settings of the LAN ports are restored, the MAINT/ID blinks green for a
few seconds.
Release maintenance status.
Use the pin to push down the FUNCTION button for three seconds.
The MAINT/ID LED turns off.
Access ETERNUS Web GUI or ETERNUS CLI by using the default IP address
to perform the network environment settings and the firewall settings.
Make sure to enable the firewall setting for the protocol that is used
IMPORTANT
for each service .
To use ETERNUS Web GUI, enable the http or https connection.
If not, the ETERNUS DX Disk storage system cannot connect to
the network via GUI.
To use ETERNUS CLI, enable the telnet or SSH connection. If
not, the ETERNUS DX Disk storage system cannot connect to
the network via CLI.
To use the "ping" command for the ETERNUS DX Disk storage
system, enable the ICMP connection. If not, the ETERNUS DX
Disk storage system does not respond to the "ping" command.
To use monitoring software, enable the Maintenance Secure con-
nection. If not, the ETERNUS DX Disk storage system cannot
connect to the network via monitoring software.
To use the SNMP Manager, enable the SNMP connection. If not,
the ETERNUS DX Disk storage system does not respond to
SNMP access.
Copyright 2011 FUJITSU LIMITED