Appendix A Event Notification Message List
A.2 Message List
Sense code
SK
04
04
04
04
04
04
04
04
04
04
04
04
04
04
06
06
06
06
06
06
06
06
06
06
06
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
ASC
ASCQ
F1
DB
CE or DE intake temperature error (sensor failure) is
detected.
F2
02
CM DMA Port is disconnected.
F2
03
CM BIOS is disconnected.
F2
04
CM RTC is disconnected.
F2
05
CM NVRAM is disconnected.
F2
06
CM EXP is disconnected.
F2
08
CM DI Port is disconnected.
F2
09
CM EXP IN port is disconnected.
F2
0A
CM EXP Out port is disconnected.
F2
0E
CM NAND Controller is disconnected.
F2
0F
CM SCU is disconnected.
F2
21
CM FPGA is disconnected.
F2
22
CM LAN Port is disconnected.
F8
00
Pinned Data occurs.
11
90
Writing of Bad Data (data lost identifier) occurs.
C1
01
CM is rebooted.
C1
10
CA is rebooted.
C1
90
IOM is rebooted.
E2
92
Disconnection of a REC path between cabinets is
detected.
F2
80
Rebuilding to a hot spare is performed.
F2
81
Rebuilding to a drive is performed.
F2
82
Rebuilding to a hot spare is complete.
F2
83
Rebuilding to a drive is complete.
F2
84
Copyback starts.
F2
85
Copyback is complete.
Copyright 2011 FUJITSU LIMITED
Description
133
Remarks
These sense codes are notified when
"Parts error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"PINNED DATA occurs" is enabled for
Error Severity Level in the event notifi-
cation setting.
They are not notified during mainte-
nance operations.
This sense code is notified when "BAD
DATA occurs" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
These messages are notified when
"Parts warning" is enabled for Warning
Level in the event notification setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"Remote path error" is enabled for
Error Severity Level in the event notifi-
cation setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"Rebuild/Copyback (Non-
Redundancy)" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during
maintenance operations.
These sense codes are notified when
"Rebuild/Copyback (Redundancy)" is
enabled for Error Severity Level in the
event notification setting.
They are not notified during
maintenance operations.